Capacitor banks and harmonic filters. Low voltage

Low voltage capacitors banks and harmonic filters for power factor correction and harmonic mitigation

Automatic capacitor banks. Low voltage

Automatic capacitor banks. Low voltage

CAB low voltage automatic capacitor banks improves power factor in systems with variable energy demand and non-linear loads, therefore, with variable reactive load needs.

Equipped with a power factor controller to regulate their automated operation and monitoring features, CAB automatic capacitor banks remove power factor charges of the electricity bill and reduce the losses of electrical equipment and wiring.

  • Eliminate charges due to a low power factor.
  • Reduce losses within the system due to Joule effect (heating).
  • Better voltage support and regulation.
  • Free-up system capacity.
  • Prevent premature equipment fail due to excessive heating cause by under voltage functioning.
  • Adjust power factor dynamically according to load profile.
  • Wide range in voltage levels from 240 to 1000 V.
  • Capacities from 30 to 1200 kvar.
  • Operation in ambient temperatures from -25 °C to 50 °C.
  • Long life cycle due to high quality low losses components and sturdy designed to work constantly at 80 °C operation temperature.
  • Single phase explosion-proof capacitors, 100% recyclable and UL certified (without potting).
  • Complete safety for the operator: Main switch operated from outside, individual discharge resistances which prevent unnecessary risks for the operator.
  • Easy installation and minimum maintenance: 100% onsite maintainable.

Documentation and Downloads

Catálogo - Bancos de capacitores automáticos BT - CAB
Caso de éxito - Calidad de energía - Datacenter
Caso de éxito - Calidad de energía - Fundición acería Thyssenkrupp
Caso de éxito - Corrección factor potencia AKAL-MB
Caso de éxito - Filtro pasabajas microturbinas gas
Caso de éxito - Filtros absorción rectificadores trifásicos
Case studies Power factor harmonic commercial facilities
Artigo técnico - Cargas dinâmicas plataforma de petróleo 2009
Technical article Dinamic harmonic mitigation power factor correction
Technical article Basic power quality definitions according IEEE-519
Technical article Causes and effects of voltage distortion
Technical article Effective value of source impedance
Technical article Avoiding harmonic resonance with low pass harmonic filters
Technical article Benefits of using low pass harmonic filters
Technical article Multiple VFDs with a single low pass filter
Technical article Theory of low pass harmonic filters operation
Technical article Why our low pass harmonic filters perform better than others
Cuaderno de Formación - Calidad de energía: compensación de energía reactiva y filtrado de armónicos
Technical article Effects of impedance on harmonic distortion
Case studies Installation of second harmonic absorption filters
Casos de sucesso - Correção fator potência AKAL-MB
Caso de éxito - Factor potencia armónicas instalaciones comerciales
Casos de sucesso - Fator potência harmônicas instalações comerciais
Casos de sucesso - Filtro passagem banda microturbinas gás
Case studies Low pass filter microturbines gas
Case studies Power factor correction AKAL-MB
Case studies Power quality datacenter
Case studies Power quality foundry steelworks THYSSENKRUPP
Casos de sucesso - Qualidade energia datacenter
Casos de sucesso - Qualidade energia fundição siderurgia THYSSENKRUPP
Artículo técnico - Mitigación dinámica armónicos factor potencia
Technical article power quality: Solutions in reactive load compensation and harmonic filtering
Brochure - Arteche Services
Catálogo de Servicios Arteche
Catálogo de Serviços Arteche

Related Products and Services